MTAG-HTA 1000V 1-pole voltage detector
TO BE USED FOR VOLTAGES max 1000 V 16 2/3 Hz
The voltage tester is intended to be used against, for example, the railway’s train heating elements.
MTAG-HTA must only be used with orange top part.
Voltage range AC 1000 V
Frequency range: 16 2/3 Hz
For indoor and outdoor environments
Group: 3 = indicates voltage active with signal. Standby mode.
Climate class: N = – 25ºC to + 55ºC depending on battery type.
Self-test: Checks circuit board and battery voltage.
Indications for use (after self-test):
Only high-intensity GREEN light => indicates absence of operating voltage.
Flashing high-intensity RED light and acoustic signal => indicates operating voltage.
Additional indications:
Flashing ORANGE LED after self-test = replace battery. If the error persists, return the tester to the supplier.
RED LED lights up steadily after self-test = return the tester to the supplier!
Bar mount: Universal type (Sunrise)
Polycarbonate casing in yellow/orange
Battery type: 9 V alkaline – IEC 6LR61
Dimensions: Ø 59 mm. L = 280 mm without electrode
Net weight: 0.390 kg
E-nr: